SUN- 5/6/8/10/12K-G03

4-15kW | Three Phase | 2 MPPT

 
 

This series inverter is specially designed for three-phase PV systems, covering a wide power range of 5kW, 6kW, 8kW, 10kW, 12kW. With compactness design, it is easy to install and operate. It supports wide AC output voltage to ensure longer working hour.

 
 
  • 2 MPP tracker, Max. efficiency up to 98.5%
  • Zero export application, VSG application
  • String intelligent monitoring (optional)
  • Wide output voltage range
  • Anti-PID function (Optional)

Product Specification

modelSUN-5K-G03SUN-6K-G03SUN-8K-G03SUN-10K-G03SUN-12K-G03
Input Side
Max. DC Input Power(kW)6.57.810.41315.6
Max. DC Input Voltage (V)11001100110011001100
Start-up DC Input Voltage(V)140140140140140
MPPT Operating Range(V)120~1000120~1000120~1000120~1000120~1000
Max. DC Input Current(A)13+1313+1313+1313+1313+13
Max. Short Circuit Current (A)30 + 3019.5+19.519.5+19.519.5+19.519.5+19.5
No. of MPP Trackers22222
No. of Strings per MPP Tracker1+11+11+11+11+1
 
Output Side
Rated Output Power(kW)5681012
Max. Active Power(kW)5.56.68.81113.2
Rated Output Voltage/Range (V)3L/N/PE 220/380V, 230/400V 0.85Un-1.1Un (this may vary with grid standards)3L/N/PE 220/380V, 230/400V 0.85Un-1.1Un (this may vary with grid standards)3L/N/PE 220/380V, 230/400V 0.85Un-1.1Un (this may vary with grid standards)3L/N/PE 220/380V, 230/400V 0.85Un-1.1Un (this may vary with grid standards)3L/N/PE 220/380V, 230/400V 0.85Un-1.1Un (this may vary with grid standards)
Rated Grid Frequency(Hz)50 / 60 (Optional)50 / 60 (Optional)50 / 60 (Optional)50 / 60 (Optional)50 / 60 (Optional)
Operating PhaseThree phaseThree phaseThree phaseThree phaseThree phase
Rated AC Grid Output Current(A)7.6/7.29.1/8.712.1/11.615.2/14.518.2/17.4
Max. AC Output Current(A)8.3/810/9.613.312.816.7/15.920/19.1
Output Power Factor0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging
Total Harmonics Current Distortion (THDi)<3%<3%<3%<3%<3%
DC Injection Current(mA)<0.5%<0.5%<0.5%<0.5%<0.5%
Grid Frequency Range45~55 or 55~65 (Optional)45~55 or 55~65 (Optional)45~55 or 55~65 (Optional)45~55 or 55~65 (Optional)45~55 or 55~65 (Optional)
 
Efficiency
Max.Efficiency98.1%98.2%98.3%98.3%98.5%
Euro Efficiency97.5%97.5%97.5%97.5%97.5%
MPPT Efficiency>99%>99%>99%>99%>99%
 
Protection
DC Reverse-Polarity ProtectionYesYesYesYesYes
AC Short Circuit ProtectionYesYesYesYesYes
AC Output Overcurrent ProtectionYesYesYesYesYes
Output Overvoltage ProtectionYesYesYesYesYes
Insulation Resistance ProtectionYesYesYesYesYes
Ground Fault MonitoringYesYesYesYesYes
Islanding ProtectionYesYesYesYesYes
Temperature ProtectionYesYesYesYesYes
Integrated DC SwitchYesYesYesYesYes
Remote software uploadYesYesYesYesYes
Remote change of operating parametersYesYesYesYesYes
Surge protectionDC Type II / AC Type IIDC Type II / AC Type IIDC Type II / AC Type IIDC Type II / AC Type IIDC Type II / AC Type II
 
General Data
Cabinet Size (WxHxD mm)283×463×178 (Excluding Connectors and Brackets)283×463×178 (Excluding Connectors and Brackets)283×463×178 (Excluding Connectors and Brackets)283×463×178 (Excluding Connectors and Brackets)283×463×178 (Excluding Connectors and Brackets)
Weight(kg)1111111111
TopologyTransformerlessTransformerlessTransformerlessTransformerlessTransformerless
Internal Consumption<1W (Night)<1W (Night)<1W (Night)<1W (Night)<1W (Night)
Running Temperature-25~60℃,>45℃ Derating-25~60℃,>45℃ Derating-25~60℃,>45℃ Derating-25~60℃,>45℃ Derating-25~60℃,>45℃ Derating
Ingress ProtectionIP65IP65IP65IP65IP65
Noise Emission(Typical)<45 dB<45 dB<45 dB<45 dB<45 dB
Cooling ConceptFree CoolingFree CoolingFree CoolingFree CoolingFree Cooling
Permissible Altitude (m)40004000400040004000
Warranty5 Years5 Years5 Years5 Years5 Years
Grid Connection StandardIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
Operating Surroundings Humidity0-100%0-100%0-100%0-100%0-100%
Safety EMC/StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
 
Features
DisplayLCD1602LCD1602LCD1602LCD1602LCD1602
InterfaceRS485/RS232/Wifi/LANRS485/RS232/Wifi/LANRS485/RS232/Wifi/LANRS485/RS232/Wifi/LANRS485/RS232/Wifi/LAN