SUN-18/20/25K-G05

18-25kW | Three Phase | 2 MPPT

 
 
 

This new series of three-phase output inverter has wider range of 18kw, 20kw, 25kw than the original series, at the same time still got two integrated MPPTs, allowing two-array to input from different roof orientations. In addition, it allows the system to be monitored and controlled remotely.

 
 
 
  • 2 MPP tracker, Max. efficiency up to 98.6%
  • Zero export application, VSG application
  • String intelligent monitoring (optional)
  • Wide output voltage range
  • Anti-PID function (Optional)

Product Specification

modelSUN-18K-G05SUN-20K-G05SUN-25K-G05
Input Side
Max. DC Input Power(kW)23.42632.5
Max. DC Input Voltage (V)110011001100
Start-up DC Input Voltage(V)250250250
MPPT Operating Range(V)200~1000200~1000200~1000
Max. DC Input Current(A)26+2626+2626+26
Max. Short Circuit Current (A)39+3939+3939+39
No. of MPP Trackers222
No. of Strings per MPP Tracker2+22+22+2
 
Output Side
Rated Output Power(kW)182025
Max. Active Power(kW)19.82227.5
Rated Output Voltage/Range (V)3L/N/PE 220/380V, 230/400V 0.85Un-1.1Un (this may vary with grid standards)3L/N/PE 220/380V, 230/400V 0.85Un-1.1Un (this may vary with grid standards)3L/N/PE 220/380V, 230/400V 0.85Un-1.1Un (this may vary with grid standards)
Rated Grid Frequency(Hz)50 / 60 (Optional)50 / 60 (Optional)50 / 60 (Optional)
Operating PhaseThree phaseThree phaseThree phase
Rated AC Grid Output Current(A)27.3/26.130.3/2937.9/36.2
Max. AC Output Current(A)30/28.733.3/31.941.7/39.8
Output Power Factor0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging0.8 leading to 0.8 lagging
Total Harmonics Current Distortion (THDi)<3%<3%<3%
DC Injection Current(mA)<0.5%<0.5%<0.5%
Grid Frequency Range45~55 or 55~65 (Optional)45~55 or 55~65 (Optional)45~55 or 55~65 (Optional)
 
Efficiency
Max.Efficiency98.6%98.6%98.6%
Euro Efficiency97.8%97.8%97.8%
MPPT Efficiency>99%>99%>99%
 
Protection
DC Reverse-Polarity ProtectionYesYesYes
AC Short Circuit ProtectionYesYesYes
AC Output Overcurrent ProtectionYesYesYes
Output Overvoltage ProtectionYesYesYes
Insulation Resistance ProtectionYesYesYes
Ground Fault MonitoringYesYesYes
Islanding ProtectionYesYesYes
Temperature ProtectionYesYesYes
Integrated DC SwitchYesYesYes
Remote software uploadYesYesYes
Remote change of operating parametersYesYesYes
Surge protectionDC Type II / AC Type IIDC Type II / AC Type IIDC Type II / AC Type II
 
General Data
Cabinet Size (WxHxD mm)362×527×220 (Excluding Connectors and Brackets)362×527×220 (Excluding Connectors and Brackets)362×527×220 (Excluding Connectors and Brackets)
Weight(kg)202020
TopologyTransformerlessTransformerlessTransformerless
Internal Consumption<1W (Night)<1W (Night)<1W (Night)
Running Temperature-25~65℃,>45℃ Derating-25~65℃,>45℃ Derating-25~65℃,>45℃ Derating
Ingress ProtectionIP65IP65IP65
Noise Emission(Typical)≤40 dB≤40 dB≤40 dB
Cooling ConceptSmart coolingSmart coolingSmart cooling
Permissible Altitude (m)400040004000
Warranty8 Years8 Years8 Years
Grid Connection StandardIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
Operating Surroundings Humidity0-100%0-100%0-100%
Safety EMC/StandardIEC/EN 61000-6-1/2/3/4,IEC/EN 62109-1,IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4,IEC/EN 62109-1,IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4,IEC/EN 62109-1,IEC/EN 62109-2
 
Features
DisplayLCD 1602LCD 1602LCD 1602
InterfaceRS485/RS232/Wifi/LANRS485/RS232/Wifi/LANRS485/RS232/Wifi/LAN